WA_DEV_GL6100_PTS_001 Rev 004 November 30, 2010 51
GL61x0 Product Technical
Specification and User Guide
Communicating with the GL61x0
Where:
When x = 0, the GL61x0 will have to be reset to start on the specified band(s);
When x = 1, the band switch is effective immediately. However, this mode is forbidden while
in Connected mode and during the GL61x0’s initialization.
Refer to document [7] Firmware 7.42 AT Commands Manual (Sierra Wireless Software Suite 2.32) for
more information regarding the AT+WMBS AT Command.
8.6. Checking the PIN Code Status
Using a communication software such as HyperTerminal, enter AT+CPIN? to check the PIN code
status. Refer to the table below for the list of main responses returned.
Table 34. AT+CPIN Main Responses
The PIN code has been entered.
The PIN code has not been entered.
Refer to document [7] Firmware 7.42 AT Commands Manual (Sierra Wireless Software Suite 2.32) for
more information regarding the AT+CPIN AT Command.
8.7. Main AT Commands for the GL6100
The table below lists the main AT Commands required for starting the GL61x0. For other available AT
Commands, refer to document [7] Firmware 7.42 AT Commands Manual (Sierra Wireless Software
Suite 2.32).
Table 35. Main AT Commands used for the GL61x0
Check network
registration
The GL61x0 is registered on
the network.
The GL61x0 is not registered
on the network; registration attempt
is ongoing.
The GL61x0 is not registered
on the network; no registration
attempt has been made.
AT+CPIN=xxxx
(xxxx = PIN code)
Incorrect PIN code (with +CMEE =
1 mode*).
PIN code already entered (with
+CMEE = 1 mode*).
+WMBS:
<Band>,<ResetFlag>
OK
The currently selected band mode is
returned.
Band switch is accepted; the GL61x0
has to be reset for the change to be
effective.