WA_DEV_GL6100_PTS_001 Rev 004 November 30, 2010 74
GL61x0 Product Technical
Specification and User Guide
Reliability Standards: Compliance and
Recommendations
Designation
Condition
RVT
Special conditions:
Density spectrum: 0.96m²/s3
Frequency range:
0.1 g
2
/Hz at 10Hz
0.01 g
2
/Hz at 250Hz
0.0005 g
2
/Hz at 1000Hz
0.0005 g
2
/Hz at 2000Hz
Slope: -3dB/octave
Acceleration: 0.9gRMS
Number of axis: 3
Operating conditions: Un-powered
Duration: 16 hours
Mechanical Shock Test
MST
Standard: IEC 60068-2-27, Test Ea
Special conditions:
Shock Test 1:
Wave form: Half sine
Peak acceleration: 30G
Duration: 11ms
Number of shocks: 8 per direction
Number of directions: 6 (±X, ±Y, ±Z)
Shock Test 2:
Wave form: Half sine
Peak acceleration: 200G
Duration: 3ms
Number of shocks: 3 per direction
Number of directions: 6 (±X, ±Y, ±Z)
Shock Test 3:
Wave form: Half sine
Peak acceleration: 100G
Duration: 6ms
Number of shocks: 3 per direction
Number of directions: 6 (±X, ±Y, ±Z)
Operating conditions: Un-powered